DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-859OPS-LINE (DS1 OPS Line)
3
1020 ABORT The test did not run due to an already existing error on the specific port
or due to a more general error on the circuit pack.
1. Examine the error log for existing errors against this port or the
circuit pack and attempt to diag nose the already existing error.
(Error code 1793 indicates a problem with the DS1 interface board,
and any problems on the associated DS1-BD or UDS1-BD should
be resolved first.)
2000 ABORT The test was aborted because response to the test was not received
within the allowable time period.
1. Retry the command at 1-minute intervals for a maximum of 5 times.
2. If the test aborts with error code 2000 again, run short test
sequence on the associated DS1-BD or UDS1-BD. If tests 138
through 145 on the associated DS1-BD or UDS1-BD are also
aborting with error c ode 2000, hyperactivity on th e b oard or facility
is indicated. In this case, the hyperactivity problem should be d ealt
with first.
2100 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute i ntervals a maximum of 5 times.
Any FAIL The NPE of the tested port did not conference the tones correctly. This
can cause noisy and unreliable connections.
1. Enter the list configuration board PCSS command. If the circuit
pack is a TN767B vintage 8 or 9, replace the circuit pack with a
TN767C V3 or later. The error log may have error type 1281 entries.
2. Test all administered trunks on the board. If one fails, this could be
an off-board problem (such as an incoming seizure or an off-hook
port seizure during the test). Retest the board.
3. If all of the ports fail, check the CARR-POW (see note below).
4. If several ports fail, check the error log for TONE-BD or TONE-PT
errors. If there are such errors, take the appropriate action. When
the TONE errors have cleared, rerun the test.
5. If the retry passes and troubles have been reported, coordinate
isolation with the far-end PBX. Make sure that the near-end and
far-end switches and any NTCE equipment (the CSUs) have the
correct administration.
6. Replace the circuit pack.
NOTE:
If the conference circuit test fails for all ports on a circuit pack, a
-5 volt power problem is indicated.
Table 3-372. TEST #7 Conference Circuit Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page