DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-713ISDN-PLK (ISDN-PRI Signaling Link Port)
3
Figure 3-22. ISDN-PRI Signaling Link Port Interactions (24 Channel -
TN767/464C)
ISDN-PLK handles maintenance and recovery for the D-channel port on the DS1
carrying the signal ing link. A problem with the ISDN-PRI Signaling Link Port
(D-channel) has an effect on all of the assoc iated DS1 ISDN Trunks or PRI
endpoint ports (B-c hannels) since no ca ll control information can b e conveyed to
the far-end switch or Terminal Adapter without it. Stable calls may remain
operational, but no new ca lls can be made.
If there are problems with the ISDN-PLK, also investigate the TN464 UDS1
interface circuit p ack (UDS1-BD).
Figure Notes
1. B- and D-channel messag es are
routed over the TDM Bus. For
additional reliability, a dup lex
D-channel can be ad ministered for
a signaling group and located on a
different TN464C (or higher) circuit
pack.
2. TN767B (or higher) or TN464C (or
higher)
Processor
(TN798)
Slot 1
DS1
Interface
circuit pack
TN767
T
D
M
b
u
s
2
(Port24)
Pimary
signalinglink
Voice o r dat a
(Port1)
Voice o r dat a
(Port23)
ISDN- TRK
(B-Channel)
ISDN- TRK
(B-Channel)
ISDN-PLK
(D-Channel)
cydfisd3 RPY 06129
7