DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-371CLSFY-PT (Call Classifier Port)
3
FAIL Hardware audit failed.
1. Run the short test sequence via the test port PCSSpp sh r 1
command.
2. If the problem persists, the system is still operating properly but
system capacity will be reduced. In order to restore system
performance to normal, replace the CLSFY-BD (Call Classifier circuit
pack) containing the defective CLSFY-PT (Call Classifier Port).
PASS The (CLSFY-PT) Call Classifier Port has passed the sanity inquiry.
Table 3-165. Tone Detector Audit/Update Test (#43) — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page