DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-443DATA-CHL (Data Channel)
3
14
16
40
2000
2003
2004
FAIL
(cont’d.)
4. If the result of Test #111 is FAIL, then the most likely problem is that the
target DATA-CHL is defective, or the Processor circuit pack is defective.
Busyout all functions that are using the Data Channels (DATA-CHLs).
!CAUTION:
All functions must be busied out because Test #107 is destructive and terminates all established connections over the DATA-CHLs.
a. Issue the test data-module <ext> long command for the target
DATA-CHL. Note the test results for Tests #107 and #108.
1. If the result of Test #107 is FAIL, then the Processor circuit pack
is defective.
(a).Replace the Processor circuit pack at your earliest
convenience. After the Processor circuit pack has been
replaced, its Time-of-Day clock must be set using the set
time command.
(b).Repeat the test.
2. If the result of Test #107 is PASS and the result of Test #108 is
FAIL :
(a).Although all DATA-CHLs are unusable, the SW-CTL is still
operational. Based on the customer’s use of DATA-CHLs,
replace the Processor circuit pack at the customer’s
convenience. After the Processor circuit pack has been
replaced, its Time-of-Day clock must be set using the set
time command.
(b).Repeat the test.
3. If the result of Test #107 is PASS and the result of Test #108 is
PASS, then the target DATA-CHL is defective.
(a).Issue the remove data-module <ext> command for the
target DATA-CHL to remove it from operation.
(b).Replace the Processor circuit pack at your earliest
convenience. After the Processor circuit pack has been
replaced, its Time-of-Day clock must be set using the set
time command.
4. Restore any busied out function (PRI-CDR/SEC-CDR, SYS -P R NT ,
PMS-PRNT/JNL-PRNT, PMS-LINK) to service before moving on
to another activity.
Table 3-188. TEST #110 Data Channel Crosstalk Test — Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page