DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-261BRI-BD/LGATE-BD (ISDN-BRI Line Circuit Pack)
3
Hardware Error Log Entries and Test to Clear
Valu es
Table 3-115. BRI-BD Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
01
1. Run the Short T est Sequence first. If all tests pass, run the Lon g T es t S equence. Refer to the appropriate
test description and follow the recommended procedures.
0 Any Any Any test board PCSS sh r 1
1(a) Any None MINOR ON
18(b) 0 busyout board
PCSS WARNING OFF release board PCSS
23(c) 0 None WARNING OFF
257(d) 65535 Control Channel
Loop Test (#52) MINOR ON test board PCSS r 20
513(e) 4352 to
4357
769(f) 4358
1025(g) 4363 NPE Audit Test
(#50)
1293
to
1294 (h)
46088
to
46096
SAKI Sanity Test
(#534) MINOR ON See footnote (h)
1537 to
1538 (i) 46082 MINOR ON
1793 (j) 46080 MINOR ON
1794 (j) 46094 MINOR ON
1795 (j) 46085 MINOR ON
2306 (j) LANBIC Receive
Parity Error Counter
Test (#595)
3330 (k) 46083 MINOR OFF
3840 (l) 4096 to
4101
3843 (m) 46097
3999 (n) Any None
Continued on next page