DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1297XXX-BD (Common Port Circuit Pack)
3
1018 ABORT There are not any translated ports on the circuit pack, or if there are ports,
then none are administered to have "neon."
1. Verify that there are ports administered on the circuit pack. If no ports
are administered, no further action is required.
2. Verify that you have neon sets connected (Lucent sets that may be
neon sets are 500 and 2500 series, also some non-Lucent may also
be neon sets). If no neon sets are connected to the circuit pack, the
test continues to abort, but no further action is required.
3. If there are no neon sets connected to the circuit pack, at least one
port needs to be translated with neon. To check if a port is translated
with neon, use the display port PCSSpp command to determine the
station extension of any station on this circuit pack. Use the display
station <extension> to determine if the port is administered with
neon. The field "Message Waiting Indicator:" must be set to "neon" for
at least one of the administered ports. If this field is not administered to
"neon" the test continues to abort. This is acceptable because not all
stations have neon lamps on their analog terminals. If none of the
terminals have neon lamps, the the test continues to abort, but no
further action is required.
4. Retry the command again.
5. Retry the command at 1-minute intervals a maximum of 5 times.
6. If the test continues to abort, look for RING-GEN errors in the Error
Log. If an ABORT 1008 occurs for this test on other circuit packs as
well, then the ringing generator may be defective. If it does not occur
on port test 48 for ANL-16-L, all four ring phases are in use.
7. Retry the command again.
2000 ABORT Response to the request was not received within the allowable time period.
2100 ABORT Could not allocate the necessary system resources to run this test.
ABORT Could not allocate the necessary system resources to run this test. Internal
System Er ror.
1. If Error Type 1538 is present in the E rr or Log, follow the r ecommended
maintenance strategy.
FAIL The test failed because no neon current was detected.
1. Look for the failure of test 220. If test 220 fails, replace the 650A power
supply.
2. Retry the command again.
Table 3-556. TEST #220 Neon Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page