DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-247ATM-TRK (Circuit Emulation Service Circuit Pack)
3
ATM Board Error Query Test (#1259)
This non-destructive ATM Error Query Test retrieves the most severe, active, on-
and off-board prob lem from the ATM-TRK circuit pack’s firmware and incremen ts
error counts in the Error Log.
The test passes if there are no errors and fails otherwise. A p assing test clears
the software counters; a failure increments the c ounter associated with the
problem that caused the failure and clears the others.
1 FAIL The circuit pack failed to reset
2 FAIL The circuit pack failed to restart.
1. Retry command.
2. If the problem persists, replace the ATM-TRK circuit pack.
PASS The ATM-TRK circuit pack is successfully reset.
0NO
BOARD No board detected.
1. Check the error log for Error 125 (wrong board) or Error 131 (no board),
and perform the appropriate repair, if needed .
2. Ensure that the board is properly translated and inserted.
3. Check for Error 1538 (hyperactivity). If hyperactive, run reset board
UUCSS.
4. Run the test again. If it fails, replace the ATM-TRK circuit pack, and
retest.
Table 3-107. ATM Board Reset (#1256) — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page