DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-77AN-LN-PT (Analog Line Port)
3
1003 ABORT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of tone detectors present or some tone
detectors may be out-of-service.
1. Resolve any TTR-LEV errors in the Error Log.
2. Resolve any TONE-PT errors in the Error Log.
3. If neither condition exists, retry the command at 1-minute intervals no
more than 5 times.
4. If the test continues to abort, escalate the problem.
1004 ABORT A valid call seized the port during the test and aborted the test.
1. Use the display port UUCSSpp c ommand to determine the station
extension.
2. Use the status station
extension
command to determine the service
state of the port.
3. If the port is in use, wait until the port is idle before testing. Retry the
command at 1-minute intervals no more than 5 times.
4. If the test continues to abort, escalate the problem.
1005 ABORT This test was aborted due to a configuration problem. The test is not
applicable for this type of analog port. This error can be ig nored.
1018 ABORT Administration has disabled the test. The default for the Test? field on the
station form is y. Determine why this field has been set to n on this station
(this may be due to the ringing application Test #48, which can be
disturbing to customer or terminal equipment).
1. To enable the test for a particular station being tested, enter change
station
extension
.
2. Change the Test? field on the station form to y.
2000 ABORT Response to the test request was not received within the allowable time
period.
2100 ABORT System resources required to run test are not available. This could be due
to a failure to seize the port.
1. Retry the command at 1-minute intervals no more than 5 times.
2. If the test continues to abort, escalate the problem.
Table 3-30. TEST #6 NPE Crosstalk Test — Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page