DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-34change system-parameters maintenance
2
Output (Page Three)
The following example shows the output from

page 3

of the change
system-parameters maintenance command.
Field descriptions (Page Three)Modem Connection
On page 3 of the example for ms, 11 fields disapp ear when the Modem
Connection? field is set to internal. In this example the Modem Connection
field is set to external, revealing the 11 fields.
The first 2 fields on page 3 estab lish the data format for transmitting serial data
from the switch to the modem. The two valid c ombinations for these 2 fields are:
Data Bits = 8, Parity = None
Data Bits = 7, Parity = (odd , even, mark, or space)
Modem Connection Valid entries are internal (default) or external.
Modem Name This field is 20 characters long and will permit alp ha-numeric
characters to provid e a unique qualifier for a g iven modem. ( )
RTS/CTS Enabled This field will inform the modem that communic ation with the data
source UART will be driven with RTS/CTS flow control. This field is
6 characters long and is case in-sensitive. (\Q3)
change system-parameters maintenance Page 3 of 3
MAINTENANCE-RELATED SYSTEM PARAMETERS
Modem Connection: external
Data Bits: 8
Parity: none
Modem Name: _______
RTS/CTS Enabled: \Q3 Auto Answer Ring Count (rings): S0=10
Asynchronous Data Mode: &M0&Q0 Dial Type: T
DTE Auto-Data Speed: ______ Adjustable Make/Break Ratio:
Disable Data Compression: ______ Dial Command: D
Enable Error Control: ______ No Answer Time-out: S7=255
Misc. Init. Param: ______________
Help/Error Message Line