DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-778MAPD-BD (MAPD Interface Circuit Pack TN802)
3
Error Log Entries and Test to Clear Values
Table 3-325. Replacing the TN802 hard drive
Step Description Comments
1. Shut down NT Shut down Windows NT by either method
described in the ‘‘Shutting down NT on the
TN802’’ section.
2. Remove the circuit pack Unlatch the circuit pack and remove it from
the carrier.
3. Remove the hard drive Remove the 2 screws and lift the hard drive
out of its mounting bracket.
4. Replace the hard drive Position the new hard drive in the mounting
bracket and replace the 2 screws (Step 3).
5. Replace the circuit pack Slide the circuit pack into the slot and lock
the latching lever.
6. Wait for initialization Wait for
the circuit pack to reseat (faceplate
LEDs light then go out
Windows NT boots (PC BOOT displays
on the faceplate LCD)
IP Trunk application to run (IP TRK #
displays on the faceplate LCD)
Continued on next page
Table 3-326. MAPD (TN802) Error Log entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
010 Any Any Any test b oard UUCSS
1 (a) 0 Circuit pack removed or
SAKI Test (#53) MIN/
WRN2ON
2 (b)
18 (c) 0 busyout board UUCSS WRN OFF release board UUCSS
23 (d) 0 WRN OFF add ds1 UUCSS
125 (e) none 3 None MIN/
WRN3ON
Continued on next page