DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-843MMI-LEV (Multimedia Interface Resource Level)
3
by failing the Archang el sanity scan test or is removed from s ervice physically b y
removing the circuit p ack from the carrier, no error/alarm is raised a gainst either
the MMI-BD or the MMI-PT maintenance objects. Therefore, if a MMI-LEV
error/alarm exists, yet no alarms have been raised against MMI-BD or MMI-PT
maintenance objects, a M MI circuit pack may have b een removed from service
causing the MMI-LEV error/alarm. To resolve a MMI-LEV MAJOR alarm, restore
the number of MMI ports availab le for service to be equal to o r greater than the
calculated p ort capacity.
To determine how many MMI circuit packs are need ed for the MMCH feature:
1. Using the display system-parameters maintenance command, locate
the number listed in the Minimum Maintenance Thresholds
(MMIs)
field and record this number.
2. Use the list configuration
command to verify the number of MMI ports.
3. Compare this number with the value listed in the MMI field on the
System-Parameters Maintenance form (number listed in step 1 a minimum
thresholds number for MMI ports of between 0-128). Each MMI circuit
pack contains a maximum of 3 2 ports. If the number in the MMIs field is
less than or equal to 32, one MMI circ uit pack is needed. If th is number is
64, then two MMI circuit pac k are needed.
4. Use the list configuration command to verify that the number of MMI
circuit packs lis ted agrees with the required minimum p ort capacity (from
step 1). If the number of MMI c ircuit packs listed in the s tep 2 differs from
the calculated numb er, restore the number of MMI circuit p acks to the
correct value, in order to resolve the MMI-LEV alarm.
Error Log Entries and Test to Clear Values
Table 3-366. MMI-LEV Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/ Off
Board Test to Clear Value
11
1. The number of MMI resources in the system that are in service has fallen below the calculated
minimum value. If the number of in-service MMI ports falls below the MMCH port capacity (value
entered in the Minimum Maintenance Thresholds for MMIs
field) on the
System-Parameters Maintenance form, a MMI-LEV error is logged. If this outage continues for 15
minutes, a MAJOR alarm is raised.
Any None MAJOR OFF