DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-796MEDPRO (Media Processor MAPD Circuit Pack)
3
To be fully administered, a MedPro circuit p ack must meet
all of these 4 conditions
:
1. Have an entry in the circuit pac k form (change circuit pack)
2. Have the MedPro ip address ad ministered (change node-names)
3. Be enabled (change ip-interface)
4. Be physically inserted into the correct slot
If the circuit pac k has an entry in the circuit pac kform and either of the
other two conditions are
not
met, a MINOR alarm is logged. To resolve the
error either
1. Make sure all conditions for ad ministration are met and that a
functioning MedPro circ uit pack is inserted in the correct slot
OR
2. Completely remove the MedPro from the system using the following
steps:
a. Remove the administered IP-Interface associated with the
circuit pack.
b. Physically remove the circuit p ack from the slot.
c. Execute the remove medpro UUCSS and change circuit
pack UUCSS commands.
b. ErrorType 18 -The MedPro Interface circuit pac k has been busied out b y
a busyout board UUCSS command.
1. Release the circuit pack (release board UUCSS).
c. Error Type 23 -The MedPro circuit pack is not c ompletely administered.
To be fully administered, a MedPro circuit p ack must meet
all of these 4 conditions
:
1. Have an entry in the circuit p lan (change circuit pack)
2. Have the MedPro IP address administered (change node-names)
3. Be enabled (change ip-interface)
4. Be physically inserted into the correct slot.
A DS1 (MEDPRO, MAP D, UDS1-BD and DS1-BD) differs from most circuit
packs in that inserting the circuit pac k into the switch is not enough to
make the board usable. It must also be administered.
d. Error Type 125 - no Aux Data: The wrong circuit pac k is inserted in the
slot where this circuit pac k is logically ad ministered.
1. Remove the wrong circuit pac k and insert the logic ally
administered circui t pack
OR