DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-285status link n
2
For general information on journal printer link s, see the description of th e
‘‘busyout journal-printer’’ section.
Output
The following example shows the output from the status journal-link
wakeup-log command.
Field descriptions
status link n
This command applies to sy stems with a C-LAN circuit pac k using Ethernet
connections. See ‘‘Output (with PI circuit pack)’’ for the screen display for
systems administered with Processor Interfac e (PI) circuit pac ks.
This command displays:
static information about the link
the modem used, connec t speed, and protocol information
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
status
journal-link
wakeup-
log
pms-log
print
printer that handles automatic
wakeup and emergency ac cess to
attendant events and scheduled
reports.
printer that handles pms down
events.
Reports print to SAT-linked printer.
init
inads
craft
cust
rcust
bcms
browse
none none
Link State If extensions are administered in the System Parameters
Hospitality form, wakeup-log s or pms-log links are c onsidered to
be administered only .
Maintenance Busy Is maintenance testing per forming on the link?
status journal-link wakeup-log
JOURNAL LINK STATUS
Link State: up
Maintenance Busy? no