DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-827MET-LINE (MET Line)

3
Table 3-358. TEST #60 MET Line Station Lamp Updates Test
Error
Code
Test
Result Description/ Recommendation
1 ABORT This port may have been busied out by system technician.
1. Look in the Error Log for Error Type 18 (port busied out) for this
port. If this error type is present, then release the port via the
release station <extension> command and run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute i ntervals a maximum of 5 times.
2 ABORT Internal System Error.
1. Retry the command at 1-minute i ntervals a maximum of 5 times.
3 ABORT Station is in ready-for-service or out-of-service state. This may be due to
wiring or an unplugged or defec tive set.
1. Make sure terminal is connected and the wiring is correct.
2. Retry the command at 1-minute i ntervals a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port
may be busy with a valid call. Use the display port PCSSpp command
to determine the station extension, attendant number, or trunk
group/member num b er of the port. Use the status station, status
attendant, or status trunk command to determine the service state of
the port. If the service state indicates that the port is in use, then the
port is unavailable for certain tests. You must wait until the port is idle
before retesting. Attendants are always in use (off-hook) if the handset
is plugged in and the port is not busied out.
1. If the port status is idle, then retry the command at 1-minute
intervals a maximum of 5 times.
FAIL Internal System Error.
1. Retry the command at 1-minute i ntervals a maximum of 5 times.
PASS MET Line Station Lamp Updates comp leted successfully.
1. If complaints still exist, investigate by using other circuit pack tests,
and by examining the station, wiring, and connections.
Continued on next page