DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-770MAPD-BD (MAPD Interface Circuit Pack TN802)
3
Table 3-323 lists the TN802 LCD messages that you might see if installing or
servicing an IP Trunk.
Support for laptop PCs
Field technicians can access the TN802 circuit p ack through:
1. ‘‘pcANYWHERE® client software’’
2. ‘‘Directly-connected k eyboard, monitor, and mouse’’
pcANYWHERE® client software
1. Attach a male-to-male serial cab le and a NULL modem c onnector
(if not built into the cable you use) to the COM2 connector (Note 8
in Figure 3-30) Attach the other end to the serial por t of your laptop.
2. Launch the pcANYWHERE® application.
3. Click on Add Remote Control Item.
4. In the Properties window, choose the communic ation port to which
you connected the c able in Step 1.
Table 3-323. TN802 LCD messag es for IP trunks
Display Explanation
PC BOOT The TN802 MAPD PC is booting up.
IP TRK # IP Trunk application is running (# character blinks)
IML DWN # Internal error on the IP Trunk. System shuts down
and sends and error message to the board .
MSHUT # where
both MSHUT and #
are blinking
The system is in the process of shutting down due to
a front panel button press. DO NOT attempt to
remove board.
MSHUT #, where #
is blinking The system has shut down gracefully.
Continued on next page