Maintenance Objects
3-83AN-LN-PT (Analog Line Port)
3
0NO
BOARD The test could not relate the internal ID to the port (no board). This result
could be due to incorrect translations, no board is inserted, an incorrect
board is inserted, or an insane board is inserted.
1. Check to make sure that the board translations are correct. Use the
list configuration command, and resolve any problems.
2. If the board is correctly inserted, issue the busy board UUCSS
command.
3. Issue the reset board UUCSS command.
4. Issue the release board UUCSS command.
5. Issue the test board UUCSS long command. This re-establ ishes the
link between the internal ID and the port.
6. If this is not the case, check to make sure that a valid board is
inserted.
Table 3-32. TEST #35 Battery Feed Test — Continued
Error
Code
Test
Result Description/Recommendation
Continued on next page