DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-64display errors
2
Form output
After completing the o ptions screen, the system dis plays a 1- or 2-page
Hardware Error Report. To toggle between the pages and to exit the report, use
the keys described below:
For 513 and 715 terminals, use F8 for NEXT PAGE and PREV PAGE commands
For all other terminals, use F7 for NEXT PAGE and PREV P AGE commands
Use Esc for the CANCEL command
The screen below is an example of an Hard ware Error Report -- Active Alarms,
without the high-resolution qualifier in the c ommand line.
Field descriptions
Extension Enter the extension number
Trunk Enter a group number or a gr oup and member numb er:
Enter
only
the group number (01-99) to display

all

members in
the group. Example: 01/__
Enter

both

the group number (01-99) and member number
(01-99) to display a

specific

member in a group. Example:
01/99.
Port Lists the location codes for the alarmed object, as follows:
Circuit packs locations display as:
cabinet-carrier-[ slot]-[circ uit]. Example: 01C702.
Port network locations display as: p ort network number-bus.
Example: PN 01B. PN 01 = Port Network (PN) number and A
or B = bus.
display errors Page 1 SPE A
HARDWARE ERROR REPORT - ACTIVE ALARMS
Port Mtce Alt Err Aux First Last Err Err Rt/ Al Ac
Name Name Type Data Occur Occur Cnt Rt Hr St
01C0702 ANL-LINE 311 257 01/31/09:20 01/31/20:26 255 256 255 a y
01C0701 ANL-LINE 1051 257 01/31/20:26 01/31/20:26 4 0 4 a y
01C0703 ANL-LINE 1053 257 01/31/20:26 01/31/20:26 4 0 4 a y
01A TDM-CLK 0 0 01/31/20:34 01/31/20:34 1 0 1 a n
01C1505 CO-TRK 078/001 3329 57408 01/31/20:26 01/31/20:27 5 300 5 a y
01C1505 CO-TRK 078/001 1537 01/31/20:26 01/31/20:28 5 150 5 a y
Command successfully completed