Maintenance Objects
3-1006SYNC (Synchronization)
3
Notes:
a. This error indicates a problem with the p rimary DS1 reference. It is cleared
when the primary reference is restored. The following steps should give an
indication of the source of t he problem:
1. Check if the primary DS1 interface c ircuit pack is inserted in the
carrier via the list configuration board PCSS command.
2. Check the connection of the c ab le supplying the external timing
source to the primary DS1 interfac e circuit pack.
3. Test the primary DS1 interface circuit pac k via the test board PCSS
long command. Check the Error Log for DS1-BD errors and refer to
the DS1-BD (DS1 Interface Circuit Pack) Maintenance
documentation to resolve any errors assoc iated with the primary
DS1 interface circuit pac k. If no errors are listed in the Error Log for
the primary DS1 interface circ uit pack, continue with the following
steps.
4. Test the active Tone-Clock circuit pack in the master port n etwork
via the test tone/clock PC long command. Check the Error Log for
TDM-CLK errors and verify that TDM Bus Clock Test #148 passes
successfully. If Test #148 fails with an Error Code 2 through 32, refer
to ‘‘TDM-CLK (TDM Bus Clock)’’ to resolve the problem. If not,
continue with the following step s.
769 (e) None MAJOR/
WARNING3OFF None
1793 40-50 None MAJOR/
WARNING OFF enable sync
2049 (f) (h)40 None WARNING OFF None
2305 (g) (h)40 None WARNING OFF None
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2. This error type initially raises a Warning alarm. If this error type persists and alarms are not
downgraded on this MO due to the value of set options, then, after a period of time, a Minor or Major
alarm is raised.
3. Major alarms on this MO may b e downgraded t o Warning alarms based on the va lue used in the set
options command.
4. It may take up to one hour for these SYNC alarms to clear due to "leaky bucket" strategy.