DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1143TONE-PT (Tone Generator)
3
Table 3-502. TEST #40 Tone Generator Transmission Test
Error
Code
Test
Result Description/ Recommendation
None ABORT The system was not able to allocate all the resources needed for this test
or there was an Internal System Error.
1 ABORT The system could not allocate all the resources needed to test the DTMF
tones.
1001 ABORT The system was not able to put the tone generation facility in the
appropriate mode to test it.
1002 ABORT The system could not allocate time slots for the test connection. This can
happen when the system is heavily loaded. If the system is not heavily
loaded, then test the TDM Bus via the test tdm port-network PN#
command. Refer to TDM-BUS section for details.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test connection. This
can happen when the system is heavily loaded or there is not a Tone
Detector circuit pack in the port network where this test is being exec uted.
1. Make sure there is a Tone Detector circuit pack installed.
2. Allow approximately 1 minute for Tone Detector maintena nce to run o n
the newly inserted Tone Detector circuit pack.
3. Retry the command at 1-minute intervals a maximum of 5 times.
1022 ABORT Tone detection for the system is administered as wide broad b and (tone
detection mode 5), and the Tone Detector used for this test was not a
TN2182. GPTD ports on other types of Tone Detector circuit packs are
taken out of service since they cannot provide the administered function.
1. Change the tone-dete c tion mode administered on the
system-parameters country-options form.
Or
2. Remove all non-TN2182 circuit packs from the system.
2000 ABORT Response to the test request was not received within the allowable time
period. System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2100 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1 (a) FAIL DTMF generation failed for the active tone generator.
105 (a) FAIL Generation of 440-Hz failed.
109 (a) FAIL Generation of 2225-Hz failed.
110 (b) FAIL Generation of 404-Hz level invalid.
Continued on next page