DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1106TIE-TRK (Tie Trunk)
3
TIE-TRK (Tie Trunk)
NOTE:
If ATMS testing is enabled, check the error log for ATMS Errors #3840 and
#3841. If the error log indicat es that measurements exceeded ac ceptable
thresholds, and if no other trouble is fo und with the test trunk command,
run the ATMS test call with the test analog-testcall port PCSSpp full
command.
The following circuit pac ks are covered by this se ction of TIE-TRK (Tie Trunk):
TN497
TN2140B
The Tie Trunk circuit pack fits into a port slot and c ontains four trunk circuits (see
Figur e 3-44 ). Each tie trunk for the TN497 circuit pac ks has 2-wire audio
connection/signal lead s (A and B).
A tie trunk port can also b e administered as an acc ess endpoint, which is a
non-signaling channel with a voice-grade d ata bandwidth.
MO Name (in
Alarm Log) Alarm Level Initial Command to Run1
1. Where P is the port network number (1); C is the carrier designation (for example, A, B, or
C); SS is the address of the slot in the carrier where the circuit pack is located (for example,
01, 02, ..., etc.); and pp is the 2-digit port numb er (for example, 01).
Full Name of MO
TIE-TRK2
2. Not relevant to the TN497 circuit pack.
MAJOR3
3. A Major alarm on a trunk indicates that alarms on these trunks are not downgraded by the
set options command and that at least 75 percent of the trunks in this trunk group are
alarmed. (This is not relevant to the TN497 circuit pack.)
test port PCSSpp l Tie Trunk
TIE-TRK MINOR test port PCSSpp l Tie Trunk
TIE-TRK WARNING test port PCSSpp sh Tie Trunk