DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-105ANN-BD (Announcement Circuit Pack)

3
Since this test involves sending a tone throug h two different ports, the Playbac k Speech Memory Array (PSMA) Test (#206) is run on the two ports first to make sure that they are working properly. See ‘‘ANN-PT (Announcement Port)’’ for a description of this test.
Table 3-40. TEST #210 140AY Loop Around Test
Error
Code
Test
Result Description/ Recommendation
1-3 ABORT Response to the test request was not received within the allowable time
period. The error code indicates at which speech c ompression rate the test
aborted (one being the first rate tested, three being the last).
1. Retry the command at 1-minute intervals a maximum of 5 times.
10 ABORT The PSMA Test (#206) failed on Announcement Port 1.
90 ABORT The PSMA Test (#206) failed on Announcement Port 9.
1. Refer to ‘‘ANN-PT (Announcement Port)’’ Maintenan ce documentation,
Test #206.
1000 ABORT System resources required to run this test are not available. This test needs
Announcement Ports 1 and 9 to run. One of the ports may be in use on a
valid call.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort and Ports 1 and 9 are not in use, escalate
the problem.
1002 ABORT The system could not allocate time slots for the test. The system may be
under heavy traffic conditions or it may have time slots out-of-service due
to TDM-BUS errors. Refer to ‘‘TDM-BUS (TDM Bus)’’ Maintenance
documentation to diagnose any active TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic,
repeat test at 1-minute intervals a maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may
be oversized for the number of Tone Detectors present or some Tone
Detectors may be out-of-servi ce.
1. Look for TTR-LEV errors in the Error Log. If present, refer to the
‘‘TTR-LEV (TTR Level)’’ Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer to the
‘‘TONE-PT (Tone Generator)’’ Maintenance documentation.
3. If neither condition exists, retry the test at 1-minute intervals a
maximum of 5 times.
1007 ABORT The Announcement circuit pack thinks that Port 1 or Port 9 is busy.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, follow the Announcement Port
maintenance procedures for Ports 1 and 9.
Continued on next page