DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1141TONE-PT (Tone Generator)
3
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order p resented in the following tables when
inspecting errors in th e system. By clearing error co des associated with the
SAKI Sanity Test
, for example, you may also clear errors g enerated from other tests in
the testing sequence.
Use the list configuration control command to find the Tone-Clock Circuit Pack
Code of the system. Then look for the Short and Long Test Sequences acc ording
to the Tone-Clock Circuit Pack Code.
For a system with a TN2182 Tone-Clock Circuit Pack
:
Notes:
a. Refer to XXX-BD (Common P ort Circuit Pack) Maintenance documentation
for descriptions of these tes ts.
b. Refer to TONE-BD (Tone-Clock Circuit Pack) section for d escriptions of
these tests.
c. Refer to TDM-CLK (TDM B us Cl ock) section for descriptions of these tests.
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND1
1. D = Destructive; ND = Nondestruc tive
SAKI Reset Test (#53) (a) X D
Clock Health Test (#46) (b) X X ND
Control Channel Loop Around Test (#52) (a) X X ND
Tone Generator Crosstalk Test (#90) X ND
Tone Generator Transmission Test (#40) X X ND
Tone Generator Audit/Update Test (#41) X X ND
TDM Bus Clock Circuit Status Inquiry Test (#148) (c) X X ND
TDM Bus Clock Slip Inquiry Test (#149)(e)(c) X X ND
TDM Bus Clock PPM Inquiry Test (#150) (c) X X ND
TDM Bus Clock Parameter Update Test (#151) (c) X X
Board Type Check Test (#574) (c) X X
Standby Reference Health Check Test (#651) (c) X