DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1294XXX-BD (Common Port Circuit Pack)
3
Control Channel Loop Around Test (#52)
This test queries the circuit p ack for its circuit p ack code and vintage and verifies
its records.
any NO
BOARD This is normal if the test is being done when (a) the circuit pack is not
physically in the system or (b) the system is booting up. Otherwise, there is
some inconsistency between the physical configuration and the data kept
in the system.
1. Verify that the circuit pack is physically in the system. Verify that the
system is not in a stage of booting up. Retry the command at 1-minute
intervals for a maximum of 5 times.
Table 3-554. TEST #52 Control Channel Loop Around Test
Error
Code Test Result Description/ Recommendation
none or
2100 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
FAIL The test failed because the circuit pack failed to return the circuit p ack
code or vintage.
1. Retry the command for a maximum of 5 times.
2. If the test still fails, issue the busyout board, reset board, and
release busy board commands, and then retest.
3. If the prob lem continues, replac e the circuit pa c k.
4. Run the test again.
PASS Communication with this circuit pac k is successful.
any NO BOARD This is normal if the test is being done when (a) the circuit pack is not
physically in the system or (b) the system is booting up. Otherwise, there
is some inconsistency between the physical configuration and the data
kept in the system.
1. Verify that the circuit pack is physically in the system.
2. Verify that the system is not in a stage of booting up.
3. ) Retry the command at 1-minute intervals for a maximum of 5 times.
Continued on next page
Table 3-553. TEST #51 Ringing Application Circuit Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page