DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-698HYB-LINE (Hybrid Line)
3
Table 3-294. TEST #59 Hybrid Line Remote Digital Loop Around Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals for a maximum of 5 times.
1 ABORT A request for a remote station audit aborted even though all internal
resources were correctly allocated.
1. Look in the error log for error type 18 (port busied out) for this port. If
this error type is present, release the port via the release port
PCSSpp command or the release station extension command, and
then run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals for a maximum of 5 times.
1000 ABORT System resources required to run this test are not available. The port may
be busy with a valid call. Use the display port PCSSpp command to
determine the station extension number of the port. Use the status station
command to determine the service state of the port. If the service state
indicates that the port is in use, then the port is unavailable for certain
tests. You must wait until the port is idle before retesting. Attendants are
always in use (off-hook) if the handset is plugged in and the port is not
busied out.
1. If the port status is idle, then retry the command at 1-minute intervals a
maximum of 5 times.
2000 ABORT Response to the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1,2,3 FAIL No response was received within the allowable time period on one of the
transmissions to the terminal. This indicates that something is wrong with
the data link to the voice terminal. This could be a sleeping set problem or
it may be due to wiring or an unplugged or d efective set.
1. Check for errors in the error l og, for example, error 1537.
2. Remotely issue the busyout and release busy commands, and run
the short test sequence on the port to check for other errors
associated with the port or terminal.
3. Check the wiring to the set if it appears that the terminal is not
responding to any tests; otherwise, replace the terminal and rerun the
test.
4. If the test still fails, replace the circuit pack and reconnect the original
terminal.
Continued on next page