DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-703HYB-LINE (Hybrid Line)

3
Hybrid Line Ringer Update Test (#62)

In this update, a "ringer on" or a "ringer off" message is sent to the firmware to

start and stop the ring er on the set.

PASS Hybrid Line Audits Test passed.
1. Although this test always return a PASS result, it ma y enter Error Types
257 or 513 into the Error Log. To determine if there are any problems
that don’t show up in the test result, look for these error types in the
Error Lo g.
2. If these errors appear in the Error Log, or if user complaints still exist,
investigate by using other circuit pack tests, and by examining the
station, wiring, and connections.
0NO
BOARD The test could not relate the internal ID to the port (no board). This could
be due to incorrect translations, no board is inserted, an incorrect b oard is
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list
config command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the
busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the
linkage between the internal ID and the port. If this is not the case,
dispatch to check to ensure that there is a valid board inserted.
Table 3-296. TEST #61 Hybrid Line Audits Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page