DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-19busyout trunk
2
number. Warning alarms (error type 18) are g enerated on each busied out
maintenance object, so that I NADS can access the state of the ob jects. The
release trunk command reactiv ates the specified trunk g roup or group memb er.
NOTE:
If the user enters busyout trunk <group number>/, the lowest
port-location in the group is busied out. This s NOT recommended.
Output
The following example is a display of the busyout trunk command.
Field descriptions
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
busyout trunk
group
member
Trunk group number (1–99)
Number of a particular trunk within
a trunk group (1 – 99)
Examples:
busyout trunk 78
busyout trunk 78/1
init
inads
craft
none none
Port Port address (cabinet-c arrier-slot-circuit)
Maintenance Name Type of busied out maintenanc e object.
Alt. Name Alternate way to identify maintenance objects.
If the Object is The field contains
station extension
trunk
xxx/yyy
(where
xxx
= trunk group numb er
and
yyy
= member number)
private CO line
P/xxx
(where
xxx
= private CO line grou p
number)
busyout trunk 78/1 SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
01C1505 CO-TRK 78/01 PASS
Command successfully completed