DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1012SYS-LINK (System Links)
3
Notes:
a. Error Type 13: indicates that the link went down. The link may have gone
down or never come up. Enter c ommand status sys-link location and
check the value of the field Faulted Path. If the value is default, then
the link never came up. If the value is present, then the link came up and
went down.
Follow the Common Procedure described above. Wait for 3 min before
checking the link state. Rep eat the procedure until there are no p roblems
with the components.
b. Error Type 257: indicates that the link has experienc ed uplink flow control.
Manifest effect of this error is that the end-p oint may be hyperac tive. The
system link is alarmed if 4 or more errors of this typ e are detected within
10 minutes.
To correct the problem, follow the Common Procedure de scribed ab ove.
Clear errors and wait for 10 minutes.
c. Error Type 513: indicates that the link has experienc ed downlink flow
control. Manifest effect of this error is that some information packets from
the packet interface b oard have been lost. The link is reset on first
occurrence, henc e, Error 1025 will also be logged . The system link is
alarmed if 2 or more errors of this type are d etected within 10 minutes.
To correct the problem, follow the Common Procedure de scribed ab ove.
Clear errors and wait for 10 minutes.
d. Error Type 772: indicates that the link experienc ed a temporary
disconnect d ue to excessive resets or state transitions. The effect of this
error is that the link is taken down and then brought up again. The system
link is alarmed if 2 or more errors of this type are d etected within 10
minutes.
To correct the problem, follow the Common Procedure de scribed ab ove.
Clear errors and wait for 10 minutes.
1537 (g) WARNING OFF test sys-link PCSSpp l cl
1793 (h) WARNING OFF test sys-link PCSSpp l cl
2049 (i) WARNING OFF test sys-link PCSSpp l cl