DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-209set options
2
If technicians set the optio n “warning” or “ report,” por t circuit pack LEDs and
LEDs on the Maintenance circuit p ack are affected the same as warning alarms.
Default parameters are:
The system downgrades all station, trunk (ex cept on-board tru nk alarms),
and Minor DS1-BD alarms to warning alarms.
On-board Major and Minor trunk alar ms, and the Memory Card Cap acity
alarm continue to raise alarms and report to INADS.
Station MOs Affected By This Command
NOTE:
Although alarms on some MOs app ear as warnings, they should be
investigated with user-repo rted problems.
Analog Lines (ANL-LINE, ANL-NE-L, ANL-16-L)
Digital Lines (DIG-LINE)
Hybrid Lines (HYB-LINE)
MET Line s (MET- LINE)
ISDN-BRI Lines (BRI-PORT, BRI-SET)
If more than 75% of the members of the trunk group alarm, minor arms escalate
to major alarms. If the trunk category op tion is set to “warning,” “minor,” “rep ort,”
or “no,” this no longer hap pens. Maintenance reac tivates individual trunk
members accord ing to Major and Minor alarm c riteria.
Trunk MOs Affected By This Command
NOTE:
Although alarms on these MOs may app ear as warnings, the alarms shoul d
be investigated with user-reported problems.
Auxiliary Trunks (AUX-TRK)
Central Office Trunks (CO-TRK)
Direct Inward Dialing Trunks (DID-TRK)
Direct Inward and Outward Dial Trunks (DIOD-TRK)
DS1 Central Office Trunks (CO-DS1)
DS1 Direct Inward Dialing Trunks (DID-DS1)
DS1 Tie Trunks (TIE-DS1)
ISDN Trunks (ISDN-TRK)
Tie Trunks (TIE-TRK)