DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-358test network-control
2
Output
The following example shows the output from the test network-control a
command. The responses d isplay on a test-by-test b asis with one line of data for
each test result.
Field descriptions
Port Port address: cabinet (al ways 1)-carrier-slot-circuit. For the
DATA-B D, SW-CTL , 12V- PWR, and CARD-M EM mai ntena nce
objects, the slot and circuit field s of port address are b lank.
DATA-CHL (administered data c hannel) uses XX as the slot
address and has a c ircuit number between 0 1 and 04. The carrier
field has a value A for the control carrier A in a simplex system.
Maintenance
Name The name of the maintenance object
Alt. Name Extension number of the DATA-CHL, if administered. For other
maintenance objects, th is field is not applic able and, therefore,
empty.
Test No The test being executed
Result Test result: Pass, Abort, Fail, No Board, Disabled, Extra Bd.
Error Code Numeric code exp laining why the release failed or ab orted. Refer
to the detailed list of the co des by test number for eac h MO.
test network-control a
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01A DATA-BD 52 PASS
01A0101 DATA-CHL 4001 109 PASS
01A0101 DATA-CHL 4001 110 PASS
01A0101 DATA-CHL 4001 111 PASS
01A SW-CTL 95 PASS
01A SW-CTL 92 PASS
01A SW-CTL 94 PASS
01A SW-CTL 324 PASS
01A 12V-PWR 701 PASS
01A CARD-MEM 695 PASS
01A CARD-MEM 696 PASS
01A CARD-MEM 697 PASS
01A CARD-MEM 698 PASS
01A CARD-MEM 699 PASS
Command Successfully Completed