DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-357test network-control
2
test network-control

This command performs hard ware diagnostic tests on a sp ecified network

control circuit pack.

!WARNING:

Since the “clear long ” options clear all c ounters if tests pass, it is poss ible

for firmware counters to be c leared even when a problem exists. In so me

cases customer servic e might degrad e since calls may be routed over

defective equip ment.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
test
network-control
location
short
long
repeat
number
clear
schedule
Network control board carrier
location (a)
Option for a brief series of
nondestructive diagnostic tests .
Option for a longer, more
comprehensive series of both
destructive and nondestruc tive
diagnostic tests.
Number of times each test in the
sequence is repeated (1-100)
This option causes the test
sequence (short or long) to repeat
until the alarm (if any) is cleared or
a single test in the sequence fails.1
Command is validated and then a
scheduling form disp lays to
schedule execution of the
command. The command is then
placed in the command q ueue and
is executed at the specified time.
The information displayed by the
command is sent to the system
printer instead of the screen.2
Examples:
test network-control
test network-control a l
test network-control b sh r 2
test network-control b l r 25
test network-control a
test network-control a c
1 If no alarms are registered against the maintenance object then the test seq uence is run only once. The
long clear
option forces a clear of all alarms if no errors are enc ountered during testing. The
short clear
option only clears
alarms pertinent to tests in the short sequence. SEE WARNING BELOW
2 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
Cabinet 1,
carrier a,
test
sequence
repeat = 1.
none