DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-37ANL-24-L (24-Port Analog Line)
3
impedance. Call the terminal equipment and verify that the term inal
rings. If the terminal does not ring , then replace it. Otherwise, issue
the test port PCSSpp command, and follow the p rocedure for
Test#48.
40977 indicates that no terminal eq uipment was connec ted when
ringing was attempted . Run the short test via the test port PCSSpp
command, and follow the p rocedure for the results of Test #48.
b. This is a software audit error that does not indic ate any hardware
malfunction. Run Short Test Sequence and investigate associat ed errors.
c. This error type indicates that the c ircuit pack has b een removed or has
been insane for more than 11-minutes. To clear the error, reseat or replac e
the circuit pack.
d. This is an in-line error and can only be resolved over time. This error
indicates that ringing voltage is absent. If only 1 analog c ircuit pack in the
system has this problem, then replac e the circuit pac k. If only analog
circuit packs o n a particular carrie r have this error, then the ringing
generator may not be connec ted to this carrier. If analo g circuit pac ks on
many carriers have this error, then it is p robably a proble m with the ringing
generator.
e. Test #48 may cause some terminal equipment to ring briefly during daily
maintenance. If this disturbs the customer or the terminal equip ment,
disable it by s ettin g the Tests field on the change station extension form
to n. On some software releases, this will also disable Tests #6, 7, 161,
and 35.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order p resented in the table be low when
inspecting errors in the sy stem. By clearing error cod es associated with the
Battery Feed Test,
for example, you may also clear errors g enerated from other
tests in the testing sequenc e.