DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-368CLSFY-PT (Call Classifier Port)
3
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order p resented in the following tables when
inspecting errors in the sy stem. By clearing error cod es associated with the
Tone Detection Verification Test
, for example, you may also clear errors g enerated from
other tests in the testing sequenc e.
Tone Detection Verification Test (#42)
This test checks out each por t in both the touch-tone receiver mod e and in the
R2-MFC tone detection/generation mode. Dur ing the first half of the test, the
touch-tone receiver mode is tested . In the second half of the test, eac h port is put
into the R2-MFC mode. During this portion of the test, eac h port’s ability to
accurately detec t and generate all forward and backward MFC tones is verified.
Table 3-163. System Technician-Demanded Tests: CLSFY-PT
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND1
1. D = Destructive, ND = Non-destructive
Tone Detection Verification Test (#42) X X ND
Tone Detection Audit/Update Test (#43) X X ND
Continued on next page
Table 3-164. TEST #42 Tone Detection Verification Test
Error
Code
Test
Result Description/ Recommendation
none ABORT The system was not able to allocate all the resources needed for this test
OR there was an internal system error
1 ABORT The system could not allocate all the resources needed to test the tones.
1001 ABORT The system was unable to put the Call Classifier port in the appropriate
mode to test it.
Continued on next page