DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-965PRI-CDR/SEC-CDR (PRI-CDR Link)
3
d. This error indicates that the CDR output devic e is in an off-line state, for
example, paper jam or p aper out for a printer device. The CDR link is torn
down. Check the CDR output dev ice and act promp tly to put it back to
on-line state. Enter test cdr-link primary|secondary command to set up
the CDR link.
e. Software detects an overflow of CDR records generated in the switc h due
to the heavy trunk traffic and low spe ed CDR output device. If b oth
primary and second ary links are ON, the secondar y link is torn down
temporarily for two minutes to speed up the output process to the p rimary
link. No action is necessary for this error type.
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order p resented in the table below when
inspecting errors in the syst em. By clearing error cod es associated with the
Link
Retry Test
, for example, you may also clear errors g enerated from other tests in
the testing sequence.
Link Tear Down Test (#213)
This test is destructive.
This test disconnects the existing link between the system and the external CDR
output device. If the link has been disconnecte d already, this test just returns
PASS. All resources allocated for an CDR link are released after this test.
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND1
1. D = Destructive; ND = Nondestruc tive
Link Tear Down Test (#213) X D
Link Retry Test (#215) X X ND