DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-410CO-TRK (CO Trunk)
3
Transmission Test (#844-848)
This test is non-destructive.
NOTE:
Tests #844-848 are not supported on a International switc h.
These tests are run by the Automatic Transmission Measuremen t System (ATMS).
They are not part of the long or short trunk test seq uences. Instead, they are run
on demand with the test analog-testcall command or as part of ATMS
scheduled testing .
The test call attempts to seize a port and make a call to a terminating test line
(TTL) on the trunk’s far end . Transmission performance measurements are made
and compared to ad ministered thresholds. Errors are generated when result s fall
outside of ‘‘marginal’’ or ‘‘unacc eptable’’ thresholds. Detail and summary
measurement reports are obtainable v ia the list testcalls command.
0NO
BOARD The test could not relate the internal ID to the port (no board).
1. Check to ensure that the board translations are correct. Translate the
board, if necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-establish the linkage
between the internal ID and the port.
Table 3-177. TEST #36 Port Audit Update Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page