DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-98ANN-BD (Announcement Circuit Pack)
3
b. Error Type 14 Whenever the Announcement Checksum Test (#209)
fails, this error is logged. The Aux Data ind icates the number of the first
defective announcement fo und. This number correspond s to the
announcement numbers on the announc ement form. The extension
relating to the announcement can b e determined by the display
announcement command. This error only appears i n the Error Log in
conjunction with Error Type 2817. Follow the procedures for Error Type
2817 to troubleshoot Error Type 14.
c. Error Type 23The circuit pac k has been logically administered but not
physically installed. The alarm is c leared when the circuit pa ck is installed.
d. Error Type 125A wrong circuit pack is inserted in the slot whe re this
circuit pack is logically administered . To resolve this problem, either
remove the wrong circuit pac k and insert the logica lly administered circuit
pack OR use the change circuit-pack command to read minister this slot
to match the circuit p ack inserted.
e. Error Type 217 and 267Indicate that there is more than one TN750
Announcement circuit p ack inserted in the system. Remove the alarmed
circuit pack.
f. Error Type 257This error indicates transient co mmunication problems
with this circuit pac k. This error is not service-affecting and no action is
required.
g. Error Type 513This error, when reported with Aux Data in the ran ge of
4352 to 4358, indicates the circ uit pack has reported a hardware failure on
the circuit pack. The circuit pack should b e replaced.
!WARNING:
Replacing the circ uit pack results in loss of integ rated announcements (TN750/B only). See ‘‘General Notes’’ near the beginning of this Main tenance procedure.
h. Error Type 1025This error is not service-affecting and no ac tion is
required.
i. Error Type 1281The SP found a fault in the speech main memory (S MM)
(that is, it found one or more faulty memory locations). Whenever this error
is logged, error 2817 is also log ged [see Note (j)] , which causes the
maintenance system to run the Announcement C hecksum Test (#209) to
determine if the bad m emory location was being used by an
announcement.
j. Error Type 1538The hyperactive circuit pac k is out-of-service and may
exhibit one or more of the following symp toms:
1. The tests run on the ports of this ci rcuit pack are returning with a
NO-BOARD.
2. A busyout/release of the c ircuit pack has no effect on test result s.