DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-652ETH-PT (Control LAN Ethernet)
3
2500 ABORT Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
FAIL Link integrity lost due to problem with attachment of Ethernet cable to the
port.
1. Repeat the test.
2. If the test fails, verify that the cable properly is secured to Ethernet port
and to the bus.
3. Verify the CLAN circuit pack link integrity LED is glowing.
4. Retry the test.
5. If problem persists, refer to Ethernet Local Looparound Test (#1278)
repair procedures.
PASS The Ethernet Link Integrity Test (#1282) detects good connections.
Table 3-270. TEST #1282 Link Integrity Inquiry Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page