DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-31ADX16A-PT (AUDIX Analog Line/Control Link)

3
Conference Circuit Test (#7)
This test verifies that the NPE channel for the port being tested can correc tly perform the conferencin g function.
2000 ABORT Response to the test request was not received within the allowable time
period.
2012 ABORT System could not respond to this request.
2100 ABORT Could not allocate the necessary system resources for this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Any FAIL The NPE of the tested port was found to be transmitting in error. This
causes noisy and unreliable connections.
1. Replace the circuit pack.
PASS The port is correctly using its allocated time slots. User-reported troubles
on thi s port sh ould be in vestigated by us ing other port tests, by exami ning
station wiring, or by examining the station.
Table 3-13. TEST #7 Conference Circuit Test
Error
Code
Test
Result Description/Recommendation
ABORT Could not allocate the necessary system resources to run this test. (a)
1000 ABORT System resources required to run test are not available. The port may be busy
with a valid call. Use the display port PCSSpp command to determine the
station extension. Use the status station command to determine the service
state of the port. If the port is in use, wait until it is idle before retesting.
1. Retry the command at 1-minute intervals a maximum of 5 times.
1004 ABORT The port was seized by a valid call during the test. The test has been aborted.
Use the display port PCSSpp command to determine the station extension.
Use the status station command to determine the service state of the port. If
the port is in use, wait until it is idle before testing.
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page
Table 3-12. TEST #6 NPE Crosstalk Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page