DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-299status station
2
Output
The following example shows the output for the status sp-link command.
Field descriptions
status station
This command displays the internal software state information for diag nosis and
to help locate the facili ties to which the station is communic ating.
Link State: Operational mode of the link:
up: the link is administered and a call is setup between the switch
and the system printer.
down: the link is administered, bu t a call is not setup between the
switch and the system p rinter.
extension not administered: the link (no system printer
extension) is not administered
Number of
Retries: Number of times the switch has tried to set up the link since a
request to set up the link was rec eived (1-999); if more than 999
retries have occurred, 999 still d isplays. (This field displays only if
the Link State: field is down.)
Maintenance
Busy? Whether any maintenance testing is bein g performed on the
system printer link:
yes and no: system printer link is ad ministered
blank: system printer link is not ad ministered.
Action/
Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
status
station
extension
print
Station extension (per dial-plan)
Report sent to printer
Examples:
status station 10020
status station 83277
status station 83277 print
init
inads
craft
cust
browse
none none
status sp-link SPE A
SYSTEM PRINTER LINK STATUS
Link State: up
Number of Retries:
Maintenance Busy? no