DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-760LOG-SVN (Login Security Violation)
3
3
LOG-SVN (Login Security Violation)
The Security Violation Notification (SVN) feature provides notification when the
number of failed attempts t o access the system adminis tration/maintenance
interface meets or exceed s customer administered threshold parameters.
A major alarm is logged whenever a security violation is d etected involving a
services login ID and that lo gin ID has been disab led as a result of the security
violation. The capability to d isable a login ID following detection of a security
violation involving that login ID is ad ministrable on a per log in ID basis.
Refer to

DEFINITY Enterprise Communications System Admini strator’s Guide

for
information on administration required for the Security Violation Notification
feature and the option to disab le a login ID following d etection of a security
violation involving the affected l ogin ID.

Hardware Error Log Entries and Test to Clear

Valu es

General Information about log-svn Error Log

Entries

a. The number (1 - 15), that appears in the error typ e field, correspond s to
the location the login in the internal login data structure.
b. The Alt Name field on the alarm report indicates the log in ID associated
with the security violation and major alarm.
c. These errors/alarms are associated with a numb er of failed attempts to
access the system manag ement/maintenance interface using a services
login ID that meet or exceed the customer administered threshold
parameters. The associated alarm is imm ediately raised as a major alarm.
MO Name (in
Alarm Log)
Alarm
Level Initial Command to Run1
1. Where <login ID> is the services login ID for which the security violation was detected. The Alt
Name field indicates the login ID associated with the security violation and the major alarm.
Full Name of MO
LOG-SVN MAJOR enable login <login ID> Login Security Violation
Table 3-319. Hardware Error Log Entries and Test to Clear Value
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
1-15 None None Major OFF enable login <login ID>