DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands

2-326test card-mem

2
!WARNING:
Since the “clear long ” option clears all c ounters if tests pass, it is p ossible for firmware counters to be c leared even when a problem exists . In some cases customer servic e might degrad e since calls may b e routed over
defective equip ment.
Feature Interactions

The test card-mem long c ommand invokes the Memory Card Erase/Write/Read

Test. This means that the save translation and save announcement commands

are rejected while the write-to-memory-c ard operation is active. This test also

invokes the Memory Card Capac ity Test which determines whether the memory

card is more than 98% full. This test is also invoked after the save translation

command.
Action/Object Qualifier Qualifier Description Permissions Defaults
Feature
Interactions
test card-mem
location
short
long
repeat
number
clear
schedule
Carrier location where memory
card resides: (
a
)
Option for a brief series of
nondestructive diagnostic tests .
Option for a longer, more
comprehensive test series
(includes a destructive test)
How many times each test in the
sequence is repeated (1-100)
This option causes the test
sequence (short or long) to repeat
until the alarm (if any) is cleared or
a single test in the sequence fails.1
Command is validated and then a
scheduling form disp lays to
schedule execution of the
command. The command is then
placed in the command q ueue and
is executed at the specified time.
The information displayed by the
command is sent to the system
printer instead of the screen.2
Examples:
test card-mem
test card-mem a l
test card-mem b sh r 2
test card-mem a sch
test card-mem a c
1 If no alarms are registered against the maintenance object then the test sequenc e is run only once. The
long clear
option forces a clear of all alarms if no errors are enc ountered during testing. The
short clear
option only clears
alarms pertinent to tests in the short sequence. SEE WARNING BELOW.
2 Refer to the Report Scheduler and System Printer feature specification for more details.
init
inads
craft
Test
sequence
= short;
repeat = 1