DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects

3-392CO-TRK (CO Trunk)

3
Notes:
a. These are in-line errors that have no specific tes t associated with them. Refer to Table 10-93 for an explanation and approp riate action.b. This is a software audit error that does not ind icate any hardware malfunction. Run the Short Test Sequence and investigate associated errors (if any).
1537 Dial Tone Test (#0) MAJ/MIN/
WRN2OFF test p ort PCSS l r 2
1793 Loop Around and
Conference Test
(#33)
MAJ/MIN/
WRN2ON test p ort PCSS l r 3
2049 NPE C ross Ta lk Test
(#6) MAJ/MIN/
WRN2ON test p ort PCSS l r 3
2561 (d) 57345 None
2817 (a) 57360 None
2817 (a) 57393 None
2817 (d) 57484 Dial Tone Test (#0) MAJ/MIN/
WRN2OFF test p ort PCSS l r 1
3073 (d) 57376 None
3329 (d) 57408 None
3329 (d) 57484 Dial Tone Test (#0) MAJ/MIN/
WRN2OFF test p ort PCSS l r 1
3585 (d) 57424 None
3840 (f) 8000 Analog Transmission
(#844-848) OFF
3841 (f) Analog Transmission
(#844-848) MINOR OFF test analog testcall PCSS
pp r 2
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
2. Minor alarms on this MO may be d owngraded to warning alarms based on the values used in the set
options command. If the Minor alarm is not downgraded by the set-options values, the Minor alarm is
upgraded to a Major alarm if 75 percent of the trunks in this trunk group are alarmed.
Table 3-171. CO Trunk Error Log Entries — Continued
Error Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page