DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-140ATM-DCH (ATM D-Channel Port)
3
Hardware Error Log Entries and Test to Clear
Valu es
Notes:
a. Error Type 18: D-channel busied out; no calls p ossible over this
D-channel.
b. Error Type 130: circuit pack removed or has been insane for more than 11
minutes. To clear the error, reinsert or replace the circuit p ack.
c. Error Type 1793: ATM Trunk circuit pac k failed the Signaling Link Board
Check (#643). Resolve any ATM-TRK errors in the Error Log.
System Technician-Demanded Tests: Descriptions
and Error Codes
The command to test the ATM-DCH maintenance object is test port UUCSSpp,
where pp is for ports 9-32.
Table 3-57. ATM D-channel Error Log entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
01
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommend ed procedures.
0 Any Any Any test port UUCSSpp2
2. pp is for ports 9-32.
18 (a) 0 busyout port
UUCSSpp
WARNING OFF release port UUCSSpp
130 (b) None WARNING ON test port UUCSSpp
1793 (c) Signaling Link Board
Check (#643) test board UUCSS l
Continued on next page