DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-154list testcalls
2
Detail report field descriptions
Group The trunk group number selec ted.
Type The trunk group type.
Vendor The vendor of this trunk group.
TTL Type The kind of test line for this trunk group.
Threshold Values The list of marginal and unacc eptable threshold values defined
on the trunk group form.
The following fields app ear on the lower section of the form. M any
of the column heading s contain the abbreviati ons “FE” for far end
and “NE” for near end. These ab breviations define whic h end
took the measurements.
Trk Mem The trunk member within the trunk group.
Test Date The month and day this trunk was tested.
Test Time The time of day this trunk was tested.
Tst Rslt This field describes the resul ts of the trunk transmission test.
1004Hz-loss Min Far-to-near and near-to-far measurements of 1004-Hz loss from
low-level tone.
1004Hz-loss Max Far-to-near and near-to-far measurements of 1004-Hz loss at 0
dBm.
list testcalls detail grp 80 Page 1 SPE A
ATMS MEASUREMENT REPORT
Group: 80 Type: co Vendor: TTL Type: 105-w-rl
THRESHOLD VALUES Loss dev at
1004Hz-loss 404Hz 2804Hz C-msg C-ntch SRL SRL
Min Max - + - + Noise Noise LO HI ERL
Marginal -2 21 9 9 9 9 55 74 0 0 0
Unacceptable -2 21 9 9 9 9 55 74 0 0 0
Trk Test Test Test -16dBm 0dBm
Mem Date Time Rslt NE FE NE FE NE FE NE FE NE FE NE FE NE FE NE FE NE FE
1
2
3
4
5
6
7
8
9
press CANCEL to quit -- press NEXT PAGE to continue