DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-673H323-SGRP (H.323 Signaling Group)
3
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order p resented in the table below whe n
inspecting errors in the sy stem. By clearing error cod es associated with the

CLAN Ethernet Status Test (#1386)

, for example, you may also clear errors
generated from other tests in the testing sequence.
CLAN Ethernet Status Test (#1386)
This test is non-destructive.
This test checks the status of the C-LAN ethernet p ort that originated this
signaling group . If the C-LAN ethernet port is in-service, the test passes, if it is
out of service the test fails.
NOTE:
Failure of this test puts the SIG-GRP in the OOS state.
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND1
1. D = Destructive; ND = Nondestruc tive
CLAN Ethernet Status Test (#1386) X X ND
MedPro Status Test (#1392) X X ND
H.323 Signaling Group Ping Test (#1387) X X ND
Table 3-281. TEST #1386 CLAN Ethernet Status Test
Error
Code
Test
Result Description/ Recommendation
2500 ABORT Internal system Error.
1. Retry the command at 1-minute intervals a maximum of 3 times
2800 ABORT A C-LAN ethernet port that corresponds to the near-end ad dress of the
signaling group has not been administered.
FAIL The C-LAN ethernet port that corresponds to the near-end ad dress of this
signaling group and all trunk members controlled b y this signaling group
are out of service.
1. Check the system for errors against the out of service C-LAN board.
Continued on next page