DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1002SW-CTL (Switch Control)
3
Table 3-445. TEST #95 Time of Day Clock Test
Error
Code
Test
Result Description/ Recommendation
1000 ABORT The test was interrupted by a higher priority task.
1. Rerun the test at 1-minute intervals a maximum of 5 times.
2. If the test aborts 5 times, wait until the system is less heavily used and
rerun the test at that time.
2012 ABORT Internal system error
2013 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2001 FAIL The Time of Day clock could not be read.
1. Run the set time command and set the time to the current time.
2. Run the Short Test Sequence several times to determine if setting the
time corrected the error. Proceed to Step 3 if the error is still occurring.
3. Replace the Processor circuit pack at the customer’s convenience .
other FAIL The accuracy of Time of Day clock is not within limits.
1. Run the Short Test Sequence several times to make sure the error is
occurring consistently.
2. Replace the Network Control (DATA-BD) circuit pack at the customer’s
convenience..
PASS The Time of Day clock on the Switch Control circuit pack is operating
correctly.
Continued on next page