DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-417CUST-ALM (Customer-Provided Alarming Device)
3
Error Log Entries and Test to Clear Values
System Technician-Demanded Tests: Descriptions
and Error Codes
There are no errors associated with the CPAD CUST-ALM MO. The test
customer-alarm PC command is p rovided to allow a technic ian to check that the
customer-provided alarming device is c orrectly installed and func tional. It is
recommended that this test b e run at least once after both the switc h and the
customer alarm have been install ed.
Always investigate tests in the order p resented in the table below whe n
inspecting errors in the sy stem. By clearing error cod es associated with the

Customer-Provided Alarming Device Test

, for example, you may also clear errors
generated from other tests in the testing sequence.
Customer-Provided Alarming Device Test (#115)
This test closes the relay that activates the CPAD for 1 minute only within the p ort
network specified. If it takes longer than 1 minute to check t hat the CPAD has
been activated, the Repeat fiel d on the test customer-alarm PC command can
be used to close the relay for up to 99 minu tes. Note that when the repeat option
is used, the results for Test #115 come back immed iately and, for each test that
passed, the CPAD is kept on for that many minutes. The CPAD does not go off
after 1 minute and then come b ack on. Instead, the CPAD is kept on continuously
for the entire time. If the CPAD is being activated and deactivated in a flic kering
fashion, there is a problem with either the CPAD or the Processor circuit p ack.
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
none none none
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND1
1. D = Destructive; ND = Nondestruc tive
Customer-Provided Alarming Device Test (#115) X X ND