DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-707INADS (INADS Link)
3
4 0 INADS did not answer the alarm origination call.
1. Verify INADS is up and running.
2. Verify the INADS phone number and switch product ID are correct via
the Maintenance-Related System Parameters Form.
3. Enable alarm origination via the Maintenance-Related System
Parameters Form and test the PR-MAINT (Maintenance/Tape
Processor) by issuing the test processor a|b command . If PR-MAINT
Tests #102 and #103 do not pass, then refer to ‘‘PR-MAINT
(Maintenance Processor)’’ Maintenance documentation.
4. Retry the command.
5 0 No INADS phone number administered.
1. Administer the INADS phone number via the Maintenance-Related
System Pa rameter s Form.
2. Retry the command.
6 0 INADS did not send the acknowledgment message to the "test inads
alarm" message.
1. Verify the INADS phone number and switch product id are correct via
the Maintenance-Related System Parameters Form.
2. Verify INADS is up and running.
3. Retry the command.
7 0 INADS sent a negative acknowledgment to the "test inads alarm"
message.
8 0 Internal system error; system received an invalid return code.
9 0 Internal system error
1. Try the command again at 1-minute intervals up to 5 times.
10 0 There is already a test inads-link command in progress.
1. Wait 10 minutes for the present command to finish.
2. Review the results of the present command by viewing the Error Log
and selecting the category "inads-link."
11 0 The switch is trying to report alarms to INADS. The test cannot be run at
this time.
1. Wait 10 minutes and retry the command.
Table 3-298. INADS Link Error Log Entries Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page