DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-385CO-DS1 (DS1 CO Trunk)
3
Table 3-170. TEST #314 DS1CO Dial Tone Seizure Test
Error
Code
Test
Result Description/ Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1000 ABORT The test was aborted because system resources required to run this test
were not available. The port may b e busy with a valid call. Use the display
port PCSSpp command to determine the trunk group/member number of
the port. Use the status trunk command to determine the service state of
the port. If the service state indicates that the port is in use, then the port is
unavailable for certain tests. You must wait until the port is idle before
retesting.
1. If the port status is active but the port is not in use (no calls), check the
error log for error type 1025 (see the error log table for a description of
this error and required actions). The port may be locked up.
2. If the port status is idle, retry the command at 1-minute intervals for a
maximum of 5 times.
1004 ABORT The test was aborted because the port was seized by a user for a valid call.
Use the display port PCSSpp command to determine the trunk
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the service state indicates that the
port is in use, then the port is unavailable for certain tests. You must wait
until the port is idle before retesting.
1. If the port status is idle, retry the command at 1-minute intervals for a
maximum of 5 times.
1005 ABORT Test failed due to incompatible configuration administered in trunk group
form.
1. Verify the following fields on the trunk group administration screen: Is
trunk direction incoming only? Is trunk the port 24 of the DS1 Interface
circuit pack while common control channel signaling is specified? Is
trunk group type the automatic CO (for example, FX)?
2. If the trunk has been administered using the above information, then
this test should abort.
1018 ABORT The test is disabled via translation. You may want to determine why the test
has been disabled before you enable it.
1. Verify that the Maintenance Test field on the Trunk Group form is
set to n. To enable the test, issue the change trunk-group x command
(x equals the number of the trunk group to be tested). Then, change
the entry in the Maintenance Test field on the form to y.
2. Repeat the test.
Continued on next page