DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Commands
2-77display system-parameters duplication
2
Field descriptions
display system-parameters duplication
This command displays the status (enabled or disab led) of Switch Processing
Element (SPE) and Port Network Connectivity (PNC) duplication. The following
must be duplicated:
Each switch node record and every switch node with its d uplicate (cab inet
administration is a prerequisite )
Every fiber link containing either an exp ansion interface circuit p ack as an
endpoint, or a DS1-C (fiber link ad ministration is a prerequisite; ci rcuit
pack administration then f ollows duplication ad ministration)
Stratum: Synchronization stratum that is used (3 or 4)
Primary: First choice system synchronization so urce (blank = no
synchronization); valid only if st ratum 4 synchronization spec ified
Secondary: Second choice system s ynchronization source (b lank = no
synchronization); valid only if st ratum 4 synchronization spec ified
Location: Circuit pack loc ation (cabinet-carrier-slot) of all administered DS1 circuit
packs are listed here.
Name: User-defined name administere d for the DS1 circuit pack. Blank means
no user-defined name adm inistered.
Slip: If the DS1 circuit pack has slip alarm, field shows y; otherwise, n.
Port
Network: Stratum 3 only; specifies the port network supplying sync hronization
through the tone clock c ircuit pack.
display synchronization Page 1 of 2
SYNCHRONIZATION SOURCE (Synchronization Plan circuit pack location)
Stratum: 4
Primary: Secondary:
DS1 CIRCUIT PACKS
Location Name Slip Location Name Slip
01C10 D92D1 ds1 1c10 n
01C11 D92D1 ds1 1c11 n
NOTE: DS1 and BRI Trunk sources result in stratum 4, type II synchronization