DEFINITY ECS Release 8.2 Maintenance for R8.2csi
555-233-119 Issue 1
April 2000
Maintenance Objects
3-1161TTR-LEV (TTR Level)
3
3. Execute the display error command. Look for a GPTD-PT, DTMR-PT, or
CLSFY-PT that has been busied out. A port that has been busied out has a
value of 18 in the error type field of the Hard ware Error Log.
For each of the busied-out po rts, use the following proced ure:
Determine why the port was busied out.
If the port can be p laced back int o service, test the port via the test
port PCSSpp command.
If all the tests pass, release the port via the rele ase port PCSSpp
command. Then wait one minute for the TTR Level alarm to clear.
If this does not clear the TTR Level alarm, proceed t o Step 4.
4. Execute the display alarm command. Determine the add ress of the Tone
Detector circuit p ack which contains the d efective (alarmed) GPTD-PT or
DTMR-PT.
Execute the test board PCSS long rep 3 command where PCSS is the
address (that is, port net work number, carrier desig nation, and slot
address) of the Tone Detector circuit pac k or Call Classifier circuit pac k
containing the defec tive (alarmed) GPTD-PT or DTMR-PT.
If this does not clear the TTR Level alarm, proceed t o Step 5.
5. At this point, the only way to clear the alar m is to replace the Tone Detector
circuit pack or Cal l Classifier circuit pack c ontaining the defective
(alarmed) GPTD-PT, DTMR-PT or CLSFY-PT.
Hardware Error Log Entries and Test to Clear
Valu es
Table 3-509. TTR Level Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
1 (a) 1 None
2 (b) 2 WARNING (See the
WARNING message
below)
OFF
3 (c) 3 None
4 (d) 4 WARNING OFF
5 (e) 5 None
6 (f) 6 WARNING OFF
7 (g) 7 MAJOR OFF
8 (h) 8 MINOR OFF
9 (i) 9 MINOR OFF